The HD 98569 is a portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature. It is fitted with a large back-lighted LCD display.
The instrument measures:
⢠pH, mV, redox potential ( ORP) with pH, redox or combined pH/ temperature electrodes complete with SICRAM module;
⢠conductivity, resistivity in liquids, total dissolved solids ( TDS) , and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
⢠Concentration of dissolved oxygen in liquids ( in mg/ l) , saturation index ( in % ) using SICRAM combined probes of polarographic type with two or
three electrodes and integrated temperature sensor.
The instrument ifs fitted with input for the measurement of temperature with Pt100 immersion, penetration or contact probes with SICRAM module.
⢠The pH electrode calibration can be carried out on one or five points and the calibration sequence can be chosen from a list of 8 buffers. Temperature
compensation can be automatic or manual.
⢠The conductivity probe calibration can be performed with automatically detected conductivity calibration solutions: 147¼ S/ cm, 1413¼ S/ cm, 12880¼ S/ cm, 111800¼ S/ cm or manually with calibration solutions having different values.
⢠The dissolved oxygen probeâ s quick calibration function guarantees longterm correctness of the performed measurements.
⢠pH, conductivity dissolved oxygen and temperature probes fitted with SICRAM module can store factory and calibration data inside.
The HD 98569 is a datalogger, it memorizes up to 200 single screens ( labels) and up to 9000 samples in continuous storage mode: pH or mV, conductivity or resistivity or TDS or salinity, concentration of dissolved oxygen and satura-
tion index and temperature.
The data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0-1.1.
The instruments equipped with HD22BT Bluetooth option can transfer the data without any connection to a PC fitted with USB/ Bluetooth converter HD USBKL1, or to the printer Sâ print-BT with Bluetooth interface or to a PC with Bluetooth input.
The serial connection RS232C can be used for direct printing of labels with a 24 column printer ( Sâ print-BT) .
The software DeltaLog11 ( vers. 2.0 and subsequent ones) allows instrument management and configuration, and data processing on PC.
Technical characteristics of HD 98569
Measured values
pH - mV- à - © - TDS - NaCl
mg/ l O2 - % O2- ° C - ° F
Instrument
Dimensions
( Length x Width x Height) 250x100x50mm
Weight 640g ( complete with batteries)
Materials ABS, rubber
Display Graphic, back lighted LCD, 56x38mm.
128x64 points
Operating conditions
Working temperature -5 ⦠50° C
Storing temperature -25 ⦠65° C
Working relative humidity 0 ⦠90% RH without condensate
Protection degree IP66
Power
Batteries 4 batteries 1.5V type AA
Autonomy ( with probes connected) 25 hours with 1800mAh alkaline batteries
Mains ( cod. SWD10) 12Vdc/ 1A ( positive at centre)
Security of memorized data
Unlimited
Time
Date and hour Schedule in real time
Accuracy 1min/ month max. departure
Continuous storage ( LOG key)
Quantity 9000 samples of the three inputs
Type organised in 1800 pages containing 5 samples each
Storage interval 1s ⦠999s
Storage on command ( MEM key)
Quantity 200 samples of the three inputs
Type organised in 200 pages containing 1 sample each
Calibration storage
pH and Dissolved Oxygen Last 8 pH and dissolved oxygen calibrations. The last 2 are saved in the SICRAM memory of the probe as well.
Conductivity Last calibration is saved in the SICRAM memory of the probe.
RS232C serial interface
Type RS232C electrically isolated
Baud rate Can be set from 1200 to 38400 baud
Data bit 8
Parity None
Stop bit 1
Flow control Xon/ Xoff
Length of serial cable Max 15m
USB interface
Typ 1.1 - 2.0 electrically isolated
Bluetooth interface
Optional for PCs fitted with Bluetooth input or HD USB.KL1 Bluetooth / RS232 adapter. The interface can be installed in Delta Ohm only.
EMC standard regulations
Security EN61000-4-2, EN61010-1 level 3
Electrostatic discharge EN61000-4-2 level 3
Electric fast transients EN61000-4-4 level 3,
EN61000-4-5 level 3
Voltage variations EN61000-4-11
Electromagnetic interference
susceptibility IEC1000-4-3
Electromagnetic interference
emission EN55020 class B
Connections
Enabled inputs for temperature
probes with SICRAM module 8-pole male DIN45326 connector
Input for pH/ temperature with
SICRAM module 8-pole male DIN45326 connector
Input for conductivity/ temperature
with SICRAM module 8-pole male DIN45326 connector
Input for dissolved oxygen/ temperature with SICRAM module 8-pole male DIN45326 connector
RS232C / USB interface 8-pole MiniDin female connector
Bluetooth Optional
Mains adapter 2-pole( Ã 5.5mm- Ã 2.1mm) . Positive at centre ( e.g. SWD10) .
Measurement of pH by instrument
Measuring range -9.999⦠+ 19.999pH
Resolution 0.01 o 0.001pH selectable from menu
Accuracy ± 0.001pH ± 1digit
Input impedance > 1012©
Calibration error @ 25° C | Offset| > 20mV
Slope > 63mV/ pH or Slope 106.5% or Sensitivity < 85%
Calibration points Up to 5 points from a list of 8 automatically detected buffers
Temperature compensation -50...150° C
Automatically detected standard
solutions @ 25° C 1.679pH - 4.000pH - 4.010pH
6.860pH - 7.000pH - 7.648pH
9.180pH - 10.010pH
Measurement of mV by instrument
Measuring range -1999.9⦠+ 1999.9mV
Resolution 0.1mV
Accuracy ± 0.1mV ± 1digit
Drift after 1 year 0.5mV/ year
Measurement of conductivity by instrument Resolution
Measurement range ( K cell= 0.01) 0.000⦠1.999¼ S/ cm 0.001¼ S/ cm
Measurement range ( K cell= 0.1) 0.00⦠19.99¼ S/ cm 0.01¼ S/ cm
Measurement range ( K cell= 1) 0.0⦠199.9¼ S/ cm 0.1¼ S/ cm
200⦠1999¼ S/ cm 1¼ S/ cm
2.00⦠19.99mS/ cm 0.01mS/ cm
20.0⦠199.9mS/ cm 0.1mS/ cm
Measurement range ( K cell= 10) 200⦠1999mS/ cm 1mS/ cm
Accuracy ( conductivity)
instrument ± 0.5% ± 1digit
Measurement of resistivity by instrument Resolution
Measurement range ( K cell= 0.01) Up to 1G© Ã
cm
Measurement range ( K cell= 0.1) Up to 100M© Ã
cm ( * )
Measurement range ( K cell= 1) 5.0⦠199.9© Ã
cm 0.1© Ã
cm
200⦠999© Ã
cm 1© Ã
cm
1.00k⦠19.99k© Ã
cm 0.01k© Ã
cm
20.0k⦠99.9k© Ã
cm 0.1k© Ã
cm
100k⦠999k© Ã
cm 1k© Ã
cm
1⦠10M© Ã
cm 1M© Ã
cm
Measurement range ( K cell= 10) 0.5⦠5.0© Ã
cm 0.1© Ã
cm
Accuracy ( resistivity) instrument ± 0.5% ± 1digit
Measurement of total dissolved solids Resolution
( with coefficient à / TDS= 0.5)
Measurement range ( K cell= 0.01) 0.00⦠1.999mg/ l 0.005mg/ l
Measurement range ( K cell= 0.1) 0.00⦠19.99mg/ l 0.05mg/ l
Measurement range ( K cell= 1) 0.0⦠199.9 mg/ l 0.5 mg/ l
200⦠1999 mg/ l 1 mg/ l
2.00⦠19.99 g/ l 0.01 g/ l
20.0⦠199.9 g/ l 0.1 g/ l
Measurement range ( K cell= 10) 100⦠999 g/ l 1 g/ l
Accuracy ( total dissolved solids)
instrument ± 0.5% ± 1digit
Measurement of salinity Resolution
Measurement range 0.000⦠1.999g/ l 1mg/ l
2.00⦠19.99g/ l 10mg/ l
20.0⦠199.9 g/ l 0.1 g/ l
Accuracy ( salinity) instrument ± 0.5% ± 1digit
Automatic/ manual temperature compensation
0...100° C with ± T = 0.00⦠4.00% / ° C
Reference temperature
0⦠50° C ( Default values 20° C or 25° C)
Conversion factor à / TDS
0.4⦠0.8
Admitted cell constants K ( cm-1)
0.01⦠20.00
Automatically detected standard solutions ( @ 25° C)
147¼ S/ cm
1413¼ S/ cm
12880¼ S/ cm
111800¼ S/ cm
n Measurement of concentration of dissolved oxygen
Measurement range 0.00⦠90.00mg/ l
Resolution 0.01mg/ l
Accuracy instrument ± 0.03mg/ l ± 1digit ( 60...110% , 1013mbar, 20...25° C)
Measurement of saturation index of dissolved oxygen
Measurement range 0.0⦠600.0%
Resolution 0.1%
Accuracy instrument ± 0.3% ± 1digit ( in the range 0.0⦠199.9% )
± 1% ± 1digit ( in the range 200.0⦠600.0% )
Salinity setting
Setting directly from menu or automatically by conductivity measurement
Setting range 0.0⦠70.0g/ l
Resolution 0.1g/ l
Temperature measurement with the sensor inside the O2 probe
Measurement range 0.0⦠50.0° C
Resolution 0.1° C
Accuracy instrument ± 0.1° C
Drift after 1 year 0.1° C/ year
Automatic temperature
compensation 0⦠50° C
Measurement of temperature by instrument
Pt100 Measurement range -50⦠+ 150° C
Resolution 0.1° C
Accuracy instrument ± 0.1° C ± 1digit
Drift after 1 year 0.1° C/ year