The HD2306.0 is a portable instrument with a large LCD display. It measures conductivity, liquid resistivity, total dissolved solids ( TDS) , and salinity using combined 4-ring and 2-ring conductivity/ temperature probes. Temperature only is measured by Pt100 or Pt1000 immersion, penetration or contact probes. The probe calibration can be performed automatically in one or more than one of the 147¼ S, 1413¼ S, 12880¼ S or 111800¼ S/ cm conductivity calibration solutions. The temperature probe is fitted with an automatic detection module, with the factory calibration settings already being memorized inside. The Max, Min and Avg function calculates the maximum, minimum or average values. Other functions include: the relative measurement REL, the Auto-HOLD function, and the automatic turning off which can also be disabled. The instrument has IP67 protection degree. INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions ( Length x Width x Height) 140x88x38mm Weight 160g ( complete with batteries) Materials ABS Display 2x41D2 digits plus symbols Visible area: 52x42mm CONDUCTIVITY METER - THERMOMETER HD2306.0 Operating conditions Working temperature -5⦠50° C Storing temperature -25⦠65° C Working relative humidity 0⦠90% RH without condensation Protection degree IP67 Power Batteries 3 1.5V type AA batteries Autonomy 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20¼ A Connections Conductivity input/ temperature probes 8-pole male DIN45326 connector Measurement of conductivity by Instrument Resolution with K cell= 0.1 0.01¼ S in range 0.00⦠19.99¼ S Measurement range ( K cell= 1) / Resolution 0.0⦠199.9¼ S / 0.1¼ S 200⦠1999¼ S / 1¼ S 2.00⦠19.99mS / 0.01mS 20.0⦠199.9mS / 0.1mS Accuracy ( conductivity) ± 0.5% ± 1digit Measurement of resistivity by Instrument Measurement range / Resolution 4.0⦠199.9© / 0.1© 200⦠999© / 1© 1.00k⦠19.99k© / 0.01k© 20.0k⦠99.9k© / 0.1k© 100k⦠999k© / 1k© 1⦠10M© / 1M© Accuracy ( resistivity) ± 0.5% ± 1digit Measurement of total dissolved solids ( with coeffi cient à / TDS= 0.5) Resolution with K cell= 0.1 0.05mg/ l in range 0.00⦠19.99mg/ l Measurement range ( K cell= 1) / Resolution 0.0⦠199.9 mg/ l / 0.5 mg/ l 200⦠1999 mg/ l / 1 mg/ l 2.00⦠19.99 g/ l / 0.01 g/ l 20.0⦠199.9 g/ l / 0.1 g/ l Accuracy ( total dissolved solids) ± 0.5% ± 1digit Measurement of temperature by Instrument Pt100 measurement range -50⦠+ 200° C Pt1000 measurement range -50⦠+ 200° C Resolution 0.1° C Accuracy ± 0.25° C Drift after 1 year 0.1° C/ year Automatic/ manual temperature compensation 0⦠100° C with ± T= 0.00⦠4.00% / ° C Reference temperature 20° C or 25° C à / TDS conversion factor 0.4⦠0.8 Cell constant K ( cm-1) 0.1, 0.7, 1.0 and 10.0 Standard solutions automatically detected ( @ 25° C) 147 ¼ S/ cm 1413 ¼ S/ cm 12880 ¼ S/ cm 111800 ¼ S/ cm